Radwag WTB 2000 Precision Balance Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messgeräte Radwag WTB 2000 Precision Balance herunter. RADWAG WTB 2000 Precision Balance User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - User Manual

User Manual Precisions scales – WTB series Manual number: ITKU-24-01-03-10-A MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMENT

Seite 2 - MARCH 2010

6. GETTING STARTED • After unpacking and mounting the scale level it out. Use levelling legs and the level condition indicator installed in the bas

Seite 3 - TABLE OF CONTENTS

8. KEYPAD Keypad of WTB series 9. KEYS’ FUNCTIONS Switching on/off Function key (operation mode selection) Sending a weighing result to R

Seite 4

10. INSCRIPTIONS ON THE DISPLAY No Text string Description 1 FIL Filter level 2 bAud Transmission baud rate 3 PCS Piece counting 4 HiLo +/- con

Seite 5 - 1. INTENDET USE

- 13 - 11. USER MENU 11.1. Submenus User’s menu is divided into 6 basic submenus. Each group has its own characteristic name preceded by the letter

Seite 6 - 2. PRECAUTIONS

11.2. Browsing user menu Use scale’s keys to move inside the menu. 11.2.1. Keypad + Entering main menu + Inscribing tare value Increasing a

Seite 7 - 4. MAIN DIMENSIONS

12. WEIGHING Put a load you want to weigh on the weighing pan. When the pictogram appears it means that the result is stable and ready to read. In

Seite 8 - 5. UNPACKING AND ASSEMBLY

12.1. Tarring In order to determine the net mass put the packaging on the pan. After stabilising press - (Net pictogram will be displayed in the l

Seite 9 - Scales WTB 200 series

• Using and set the tare value, • Press , • Program returns to weighings mode. The inscribed tare value can be seen on the display with „–” sig

Seite 10 - 7. BALANCE LEVELLING

12.5. Selection of basic weight unit This function is used to set weight unit the scale will start with. Procedure: • Enter the submenu <P

Seite 11 - 9. KEYS’ FUNCTIONS

• After you select the unit press , the scale returns to: • Return to weighing according to chapter - 11.2.2. Notice: After turning on the sca

Seite 12

- 2 - MARCH 2010

Seite 13 - 11. USER MENU

Options: A. When [kg] is a basic unit, users can select following units: [kg, lb, N], [lb] is not accessible for verified scales; B. When [g] is

Seite 14

Notice: Filtering level influences the time of stabilization. The higher the filtering level is the longer stabilization time is needed. Return to w

Seite 15 - 12. WEIGHING

13.3. Autozero function The autozero function has been implemented in order to assure precise indications. This function controls and corrects „0” i

Seite 16

13.4. Tare function This parameters enables users to configure a tare function. Procedure: • Enter the submenu <P1.rEAd> and then: tArA

Seite 17 - and set the tare value

14. RS 232 PARAMETERS External devices connected to RS 232C have to be supplied from the same mains and common electric shock protection. It preven

Seite 18

Pr_n noStAb - immediate printout (not accessible in verified scales) Pr_n StAb - sending stable results Pr_n rEPL - automatic operation Pr_n CntA

Seite 19

Return to weighing: see 11.2.2. 14.3. Baud rate Procedure: • Enter the submenu <P2.Prnt> and then: - 26 -

Seite 20 - 13. MAIN PARAMETERS

Return to weighing: see 11.2.2. 14.4. Serial transmission parameters Procedure: • Enter the submenu <P2.Prnt> and then: 7d2SnP - 7 da

Seite 21

15. OTHER PARAMETERS The user can set parameters which influence the scale operation. They are gathered in the submenu <P5.othr> e.g. backlig

Seite 22

Return to weighing: See 11.2.2. Notice: When bl=Auto, and the indication has not changed for 10s, the backlight is automatically switched off. The

Seite 23

- 3 - TABLE OF CONTENTS 1. INTENDET USE...

Seite 24 - 14. RS 232 PARAMETERS

15.2. “Beep” signal – after pressing a key Procedure: • Enter the submenu <P5.othr> and then: bEEP no - switched off bEEP YES - sw

Seite 25

* automatic enabling/disabling according to the source of power. Procedure: • Enter the submenu <P5.othr> and then: Returnto weighing: Se

Seite 26

Procedure: After displaying the level of batteries (in per cents) the program returns to weighing. 15.4.2. Battery discharge pictogram The sym

Seite 27

• Message „nImh” appears on the display, • In case of damaging accumulators or lack of it the pictogram blinks quickly (period about 0.5 sec). No

Seite 28 - 15. OTHER PARAMETERS

Procedure: 1. Supply the indicator from mains. 2. Charge batteries for 12 hours (time of charging 2200mAh batteries). 3. After 12 hours unplug fro

Seite 29

no – mode is disabled YES – mode is enabled Return to weighing: See 11.2.2. 16.2. Selecting quantity of operation modes This function enab

Seite 30

16.3. Counting pieces of the same mass Standard solution is equipped with option of counting small pieces of the same mass. It is possible to execut

Seite 31

• If option <LASt> is choosen in the scale program displays estimated unit mass of the last piece (about 3 sekonds) and then goes to Counting p

Seite 32

Notice: 1. If a user presses the key when load is not present on the pan, the message -Lo- will be indicated for a few seconds and the scale will

Seite 33

• The inscribed value confirm by pressing , the program will automatically go to the higher threshold of weighing (Max): • The inscribed valu

Seite 34 - 16. OPERATION MODES

- 4 - 16.3. Counting pieces of the same mass ... 36 16.4. +/- control referri

Seite 35

Return to weighing: • Press the key twice. 16.5. Control of % deviation referring to the inscribed standard mass Scale software enables control

Seite 36

Return to weighing: • Press the key twice. 16.5.2. Mass of standard inscribed to scale memory Procedure: • Enter to <PrcB> function:

Seite 37

Return to weighing: • Press the key twice. 16.6. Automatic tare This function is useful for fast net mass determination of weighed load in cas

Seite 38

16.7. Measurement max force on the pan – latch Procedure: • Enter to <toP> function: • Confirmation of choice of <toP> function is

Seite 39

16.8.1. Enabling the work mode Procedure: • Enter to <Add> function: • A letter „P” in the left side of the display is a confirmation tha

Seite 40

• Take off the load from the pan, indication returns to ZERO and the letter „P” in the left part of the display appears, • Put the next load on t

Seite 41

- In order to continue the procedure press , the indication returns to ZERO and the letter „P” appears in the left part of the display. The scale

Seite 42

16.9. Weighing animals Procedure: • Enter to <AnLS> function: • The <tinnE> message appears on the display for 1s, and then the pro

Seite 43

• Load an animal to the platform, • After exceeding the -LO- value (see 14.2), program starts the weighings process. The appearance of subsequent

Seite 44 - when stable

16.10.1. Entering the tare value to the scale memory Procedure: • Enter to <tArE> function: • The program goes to displaying the first v

Seite 45 - TOTAL: 3.824 kg

- 5 - 1. INTENDET USE Scales are designed for fast and precise measurements of weighed loads masses and direct commercial settlements. Tarring in fu

Seite 46

• Enter the selected tare value to the scale memory , • The program returns to the following window: Return to weighing: • Press . 16.10.

Seite 47

17. USER CALIBRATION Only for non-verified scales Confirmation of high accuracy of weighing requires periodical correcting of calibration factors i

Seite 48 - • Press

• Place the required weight on the pan, • Calibration process starts automatically after placing the adequate weight that is signalled by the foll

Seite 49

17.2. Start mass adjustment If the scale does not require the full calibration process sit is possible to adjust only a new start mass. Procedure:

Seite 50

• Return to weighing performing the procedure of saving parameters. Return to weighing: See 11.2.2. Caution: If the start mass adjustment lasts

Seite 51 - 17. USER CALIBRATION

Cable diagrams: Scale – Kafka printer cable diagram 19. COOPERATION WITH COMPUTER Sending weighing results to the computer can be done: - man

Seite 52

- 56 - 20. COMMUNICATION PROTOCOL 20.1. General information A. A character protocol scale-terminal has been designed for communication between RAD

Seite 53

- 57 - 20.3. Respond message format After sending a request message you can receive: XX_A CR LF command accepted and in progress XX_D CR LF comma

Seite 54 - 18. COOPERATION WITH PRINTER

- 58 - T_A CR LF T_D CR LF - command accepted and in progress - command completed T_A CR LF T_v CR LF - command accepted and in progress - command

Seite 55

- 59 - Frame format: 1 2-3 4 5 6 7-15 16 17 18 19 20 21 S space stability space sign mass space unit CR LF Example: S CR LF – computer command

Seite 56 - 20. COMMUNICATION PROTOCOL

2. PRECAUTIONS 2.1. Maintenance A. Please, read carefully this user manual before and use the device according to its intended use. B. Devices t

Seite 57

- 60 - SU_A CR LF SU_E CR LF - command accepted and in progress - timeout while waiting for stable results SU_I CR LF - command comprehended but can

Seite 58

- 61 - 20.4.8. Switch on continuous transmission in basic unit Syntax: C1 CR LF Possible answers: C1_I CR LF - command comprehended but cannot be

Seite 59

20.4.11. Switch off continuous transmission in current unit Syntax: CU0 CR LF Possible answers: CU0_I CR LF - command comprehended but cannot be

Seite 60

- 63 - Stability character [space] if stable [?] if not stable [^] if an indication over the range [v] if fan indication below the range sign [space

Seite 61

- 64 - Stability character [space] if stable [?] if not stable [^] if an indication over the range [v] if fan indication below the range sign [space

Seite 62

- 65 - NULL - Zero value from the AD converter FULL2 - Measurement range overflow LH - Start mass error, the mass on the weighing platform is beyon

Seite 63

- 66 - 23. TECHNICAL PARAMETERS Scale type: WTB 200 WTB 2000 WTB 3000 Max capacity 200g 2000g 3000g Readability 0,001g 0,01g 0,01g Range of ta

Seite 64 - 21. ERROR COMMANDS

MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMENTS RADWAG WAGI ELEKTRONICZNE 26 – 600 Radom, Bracka 28 Street POLAND Phone +48 48 384 88 00

Seite 65 - 22. TROUBLE SHOOTING

3. WARRANTY CONDITIONS A. RADWAG is obliged to repair or change those elements that appears to be faulty because of production and construction re

Seite 66 - 24. ADDITIONAL EQUIPMENT

Scales WTB 200 series Scales WTB 2000…3000 series 5. UNPACKING AND ASSEMBLY Unpack and put the scale on a flat even stable surface far

Seite 67

Scales WTB 2000…3000 series • Install the pan according to the drawing below: Scales WTB 200 series Scales WTB 2000…3000 series

Kommentare zu diesen Handbüchern

Bernard Koffi 30 Oct 2024 | 06:58:38

Best Manual