RADWAG WTB series Bedienungsanleitung Seite 63

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 65
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 62
23. TECHNICAL PARAMETERS
Scale type: WTB 600 AU WTB 1200 AU
Max capacity 600g 600g
Accuracy of mass reading 0,01g 0,01g
Tare range -600g -1200g
Accuracy of gold caratage reading 0,1K
Accuracy of density reading 0,001g/cm
3
Accuracy of volume reading 0,001cm
3
Accuracy of % content reading 0,01%
Accuracy of platinum class reading 1PT (1-1000PT)
Repeatability 0,03g
Linearity ±0,03g
Stabilization time 3 sec
Pan size 125 x 145mm
Working temperature +15°C to +30°C
Power supply 230V AC 50Hz / 11V AC, 6×AA NiMH
Average operation time on batteries 35h
Display LCD (with backlight)
Interface RS 232
Dimensions 244x178x182mm
24. TROUBLE SHOOTING
Problem Cause Solution
Discharged batteries
Connect to mains or
change batteries
Balance does not turn
on
No batteries (not installed
or improperly installed)
Check the correctness of
installation (polarization)
The balance turns off
automatically
“t1” set to „YES” (Power
saving mode)
Go to submenu “othr” and
change “5.4 t1” to “no”
After turning on „LH”
message on the display
Load on balance’s
weighing pan during
powering up
Unload the pan. The
balance should indicate
zero.